热门关键词:
服务咨询热线:
021-56633066
密封完整性专区

       

        技术文献

  • 11 2024-12

    The Application of Noninvasive Headspace Analysis to Media Fill Inspection

    The Application of Noninvasive Headspace Analysis to Media Fill Inspection
    ABSTRACT: The results of a proof-of-principle study demonstrating a new analytical technique for detecting microbial growth directly in pharmaceutical containers are described. This analytical technique, laser-based headspace analysis, uses tunable diode laser absorption spectroscopy to nondestructively determine gas concentrations in the headspace of a media-filled pharmaceutical container.

  • 11 2024-12

    Importance of Container Closure Integrity in Autoinjector

    Importance of Container Closure Integrity in Autoinjector
    Definition of CCIT
    • Container Closure Integrity Testing (CCIT) is an assay that evaluates the adequacy
    of container closure systems to maintain a sterile barrier against potential
    contaminants.
    • Contaminants that could potentially cross a container closure barrier include
    microorganisms, reactive gases, and other substance.
    • CCIT is commonly referred to as leak detection.
    • Leak: There are many risks associated with glass, including issues such as
    breakage, delamination, leachable, and physical and chemical compatibility with the
    drug product itself that can affect the safety and efficacy of a pharmaceutical product.

  • 11 2024-12

    GUIDELINES The Rules Governing Medicinal Products in the European Union Volume 4 EU Guidelines for Good Manufacturing Practice for Medicinal Products for Human and Veterinary Use

    GUIDELINES
    The Rules Governing Medicinal Products in the European Union
    Volume 4 EU Guidelines for Good Manufacturing Practice for Medicinal Products for
    Human and Veterinary Use
    The manufacture of sterile products covers a wide range of sterile product types (active substance, excipient, primary packaging material and finished dosage form), packed sizes (single unit to multiple units), processes (from highly automated systems to manual processes) and technologies (e.g. biotechnology, classical small molecule manufacturing systems and closed systems). This Annex provides general guidance that should be used in the design and control of facilities, equipment, systems and procedures used for the manufacture of all sterile products applying the principles of Quality Risk Management (QRM), to ensure that microbial, particulate and endotoxin/pyrogen contamination is prevented in the final product.

  • 11 2024-12

    2022The science The behind the integrity of single-use system: InvInvestigating estigating liquid leak and micrand microbial ingrobial ingress mechanisms ess ttoo determine the maximum allowable leakage limit

    2022The science The behind the integrity of single-use system: InvInvestigating estigating liquid leak and micrand microbial ingrobial ingress mechanisms ess ttoo determine the maximum allowable leakage limit
    Integrity is a critical guality attribute of our single-use systems as an integrity breach can have dramatic impacts on patientsafety, operator safety or drug availability. Growing industry scrutiny of single-use system integrity (SUSl) is raising the needto develop good science behind reliable determination of liquid leakage and microbial ingress, as well as the appropriatephysical integrity testing technologies. The results of the experiments performed to understand the mechanisms of liquidleakage and microbial ingress of SUSl are presented. A relation between liquid leakage and microbial ingress mechanismsin single- use plastic containers are confirmed. Microbial ingress testing by the aerosolization and the liquid leakage test areused to determine the maximum allowable leakage limit (MALL). Statistical analvsis indicated the probability of MALL at acertain defect size for each system.
    With additional experiments a correlation between a certain defect size and the corresponding gas flow rate is found. TheMALL defined as a gas flow rate will link to a physical integrity testing system.The methods provide an accurate way of predicting ingress, increasing safety down the line for drug manufacturers andpatients alike.

  • 11 2024-12

    Ozone Detection in Pharmaceutical Containers

    Ozone Detection in Pharmaceutical Containers
    Pharmaceutical vials are subjected to a high voltage leak detection (HVLD) test. A
    high voltage (up to 30kV) is passed across the surface of the vial and the presence
    of a crack is detected through a change in the current. HVLD has been linked to
    the breakdown of active pharmaceutical ingredients (APIs) and it is hypothesised
    that ozone, a strong oxidising agent, generated as a consequence of the high
    voltage, is responsible. (1) It is crucial that the manufacturing process is designed
    to minimise any changes to the molecular structure of biopharmaceuticals and
    this extends to ensuring that container integrity testing does not cause product
    degradation.